Fire Alarm System

Combined detectors

  • Lightning-fast detection and reporting of incipient fires

  • Optimum inflow response

  • Combined detection methods

  • Cubus levelling to adapt to ambient conditions

  • Continuous self-monitoring and dirt level evaluation

  • Easy maintenance

  • Extensive programming functions

  • Easy mounting and integration in fire detector systems

  • Elegant design

  • Integrated short-circuit insulators

  • Complies with standards EN 54-5 (temperature detection), EN 54-7 (smoke detection), EN 54-26 (CO detection), EN 54-29 (algorithm of temperature and smoke detection) and EN 54-30 (algorithm of CO and temperature detection)

Smoke detectors

  •  Rauchmelder nach EN 54-7 

  •  Temperatures setup

  •  Digital Signal overbearing

  •  Collective Addressing

  •  Smoke detector compliant with EN 54-7

  •  Temperature-supported scattered light principle

  •  Digital signal processing

  •  Collective addressing

Fire Alarm Control Panel

  • Two Loop Control Panel, 230Vac, 2 sounder circuits. Dims 391.5 x 390 x 147mm (H x W x D)

  • The DX Connection is an enhancement of the Morley-IAS Dimension panel range, connecting the traditional Morley-IAS qualities of reliability, flexibility and value with advanced features and intuitive functionality.

  • The multi-protocol DX Connection range of fire alarm control panels has been developed to be the most time effi cient fi re panel on the market to install. DXc Control panels are supplied without zone LEDs.

  • In order to connect panels together to create a network a DXc Network card and DXc Control panels are supplied without zone LEDs.

Sounders Conventional

  • Volume up to 112 dB(A)

  • Can be used in adverse environmental conditions

  • For 12 V DC and 24 V DC

  • Reverse polarity protection

  • Available for surface and flush-mounted cable feed

Optical beam smoke detectors

  • The 6500RS and 6500R are conventional reflector- type linear optical beam smoke detectors designed to operate as a component of a conventional fire alarm system. They operate primarily on the principle of light obscurantist utilizing an infra-red beam. Optical beam smoke detectors are particularly appropriate for protecting buildings with large open spaces such as warehouses, atrium etc. Download the System Sensor datasheet

  • • Combined transmitter and receiver unit

  • • Range 10–100 metres

  • • 4 x fixed sensitivity/threshold levels

  • • Numerical indicators to aid beam alignment

  • • Standby, fault and alarm LED indicators visible from the front and bottom

  • • ±10° horizontal and vertical beam alignment

  • • Automatic drift compensation

Sounder Strobes

  • High quality loop powered device designed to alert building occupants of an emergency. Featuring fast and simple installation and control it is powered by the fire panel via the loop wiring. Control of the device is enabled using on-board switches or via the digital protocol using the control panel.

  • WSO-PR-N00 - Red Wall Mount Sounder, with pure white skirt - non isolated.

  • WSO-PR-I00 - Red Wall Mount Sounder, with pure white skirt - isolated.

  • The range is installed simply by a twist fit onto the B501AP base.

Single Channel Input Module

  • The MI-DMMI and MI-DMM2I monitor modules are used with the Morley-IAS intelligent fire alarm control panels to provide a single or dual input circuit from external devices. Each input is continuously monitored for normal, open circuit and alarm conditions. Changes to the status of the input circuits are communicated to the panel where the appropriate actions may be undertaken. The MI-DMMI requires a single address and the MI-DMM2I two addresses of the ninety-nine possible module addresses available on a loop. It responds to regular polling from the control panel indicated by a pulsing LED every successful communication. The MI-DMMI and MI-DMM2I use a unique mechanical design allowing each module to be mounted either in a wall box (M200E-SMB) or on a DIN rail (using M200E-DIN). Irrespective of the mounting method chosen, the address switch is both visible and accessible for selection. To help engineers in the maintenance and fault finding process, both the LEDs and the address switches can be viewed without having to remove the cover of the mountng box. The LEDs, being multi colour, provide diagnostic information regarding the status of the output. For ease of installation, testing and maintenance, the field wiring terminals are of a plug in design.

Typical System Schematic

  • High quality loop powered device designed to alert building occupants of an emergency. Featuring fast and simple installation and control it is powered by the fire panel via the loop wiring. Control of the device is enabled using on-board switches or via the digital protocol using the control panel.

  • WSO-PR-N00 - Red Wall Mount Sounder, with pure white skirt - non isolated.

  • WSO-PR-I00 - Red Wall Mount Sounder, with pure white skirt - isolated.

  • The range is installed simply by a twist fit onto the B501AP base.

  • Present Address

  • H.No 11-13-109/2n, Plot.No.19,Margadarshi Colony, Kothapet, Hyderabad - 500102,Telangana, India.

  • Phone : 040 - 24033520.

  • Mobile : 9849010384, 9949010384.